DHT-DMH-4810 / DHT-DML-4810 provides 2 chambers with 24 BIB slots each, 48 slots total, and a standard -20 to +150 °C range. These memory burn-in answers separate equipment ratings from test conditions and project acceptance.

4810 burn-in test conditions and acceptance

Does the 4810 heat-load rating guarantee the same uniformity at every load?

No. DHT-DMH-4810 / DHT-DML-4810 has a stated heat-load range of 3.5 to 10 kW. The published uniformity is measured at 6.5 kW: ±3.0 °C from -10 to +125 °C and ±4.0 °C from +125 to +150 °C. Do not extend those uniformity values to a different load or temperature segment without engineering agreement.

Can the published 4810 ramp times be used at 10 kW?

The published heating and cooling segments are specified with a 5.5 kW load. They do not establish ramp times at 10 kW. Give DHT the actual dissipated load, board population, temperature endpoints and acceptance method so the project profile can be reviewed.

Does independent temperature control prove complete thermal isolation?

The two 4810 chambers have independent temperature control; one can operate while the other is opened for BIB loading and unloading. This operating capability does not establish a quantified disturbance limit for the running chamber. Agree the temperature monitoring and door-opening acceptance procedure for the project.

Does the 4810 total 126 kVA rating replace a branch-circuit schedule?

No. The published 126 kVA total is a facility-planning reference. The equipment schedule also identifies the right-chamber circuit ELB-R1, left-chamber circuit ELB-L1 and refrigeration circuit ELB-REF. Review the approved electrical drawings, supply voltage and circuit allocation before arranging site connections.

Does a 4810 chamber specification establish a device burn-in recipe?

No. The 4810 is a dual-chamber platform with 48 BIB slots and a standard -20 to +150 °C range. Tester electronics, BIBs, programs and device stress conditions must be agreed for the application. Chamber temperature and slot count alone do not validate a device recipe or predict devices per hour.

4810 dual-chamber burn-in

Frequently asked questions

How many burn-in boards does the 4810 hold?

Each of the two chambers has 24 BIB slots, giving 48 slots in total. These are arranged as 4 sites with 12 slots per site.

Do DMH-4810 and DML-4810 use the same chamber?

Yes. Both use the 2-chamber, 48-slot platform. DMH interfaces with high-speed testers using high-speed multi-pin connectors. DML interfaces with low-speed testers at ≤10M using low-speed edge-finger (gold-finger) connectors. DML-4810 has standard manual doors and manual BIB loading/unloading; automatic doors and automatic BIB insertion/removal are optional.

Can the two 4810 chambers run at different temperatures?

The two chambers have independent temperature control, for example +125 °C in one chamber and +85 °C in the other. While one chamber is running, the other can be opened for BIB loading and unloading.

What if the process needs -40 °C or -60 °C?

The standard 4810 reaches -20 °C. For lower temperatures, choose DHT-DMH-4860, with a range of -60 to +150 °C.

What if the 4810 heat load exceeds 10 kW?

The 4810 allows a heat load of 3.5 to 10 kW. For loads above 10 kW or high-power devices such as HBM, work with DHT engineering to assess airflow and heat removal.

What conformity coverage does the 4810 have?

The 4810 platform is CE marked and SEMI S2 evaluated. DHT operates an ISO 9001 certified quality management system.

Can the 4810 be supplied for a US factory?

A 480 V / 60 Hz configuration is available. A UL/ETL field evaluation can be arranged separately if required by the factory.

What are the warranty and lead time?

The equipment warranty is 3 years and the standard lead time is 3 months.

Are the tester and burn-in boards included?

No. The 4810 is a chamber platform. The customer or tester manufacturer supplies the test electronics, burn-in boards and test programs for the project. DHT handles chamber-side interfaces and joint integration.

4810 dual-chamber burn-in selection and planning

How many devices per hour can a 48-slot line process?

Slot count alone does not establish throughput. Agree devices per BIB, occupied slots, usable capacity, dwell, ramps, handling, scheduling and availability. The line-sizing article gives a transparent planning equation; no customer production result is claimed.

4810 full specifications and utility tables

DMH-4810 product selection

DMH-4810 chamber parameters and utility schedule · Burn-in product overview

Model-specific burn-in reference parameters

Parameter Specification
Reference models DHT-DMH-4810 / DHT-DML-4810
Chamber temperature range -20 to +150 °C
BIB slots 2 chambers × 24 slots = 48 slots
Heat-load range 3.5 to 10 kW

These ratings apply to the model and configuration shown. Agree device stress recipes and acceptance criteria for each project.

Which devices are covered by the DML 2410 specification?

The system supports eMMC, UFS 2.2, UFS 3.1 and UFS 4.1. The configuration uses 24 BIBs × 144 devices = 3,456 devices per batch. Agree BIB interfaces, firmware and the device test plan separately.

How should I compare temperature uniformity?

Compare the stated load condition as well as the value. DML 2410 and DML 2450 specify ≤ ±2 °C with no load and ≤ ±3 °C at full load. Agree the test method and sensor arrangement before acceptance.

Can I order a chamber for my own tester?

DHT offers OEM chamber work. The DMH 3250 specification includes automatic BIB insertion and removal and tester interlock communication. Mechanical layout and slot definition require confirmation.

What voltage options are available?

Standard 380–400 V / 50 Hz and optional 480 V / 60 Hz are available options. Final connection and installed power depend on the approved equipment configuration.

How can I discuss a burn-in system configuration?

Email sales@doaho.com with the device type, temperature profile, devices per batch, tester scope and site voltage/frequency, or call +86 21 5749 4498.

How many devices does the DHT-DML-2410-S100TC burn-in system hold?

The 24-BIB configuration uses 144 devices per BIB, for 3,456 devices per batch. This capacity applies to that specified board population.

What are the DHT-DML-2410-S100TC facility ratings?

For the 24-BIB configuration: approximately 3,500 kg equipment weight, 45 kW installed power, 50 kVA specified switch capacity and CDA dew point ≤ -40 °C. Final site connections require project approval.

3410 burn-in platform identification

Are DCSD200C, SDH-3410 and GPU-3410 the same platform?

DCSD200C is the export model name of the 3410 platform, also named SDH-3410 and GPU-3410. The confirmed platform has a -20 to +150 °C temperature range, 34 slots and 1 chamber, with CE marking and SEMI S2 evaluation coverage. Project interfaces and acceptance conditions require approval.