chambres d'essai

Liste de vérification de l'entretien quotidien pour les enceintes de test de laboratoire

Écrit par Robin
Ingénieur principal, Doaho Test (DHT®)

Why Is Daily Maintenance of Expansibilité fonctionnelle : Les modules optionnels pour l'éclairage, le faible oxygène ou les tests de stress mixte permettent une couverture d'application plus large. Essential?

Benchtop test chambers are compact, multifunctional environmental testing devices widely used in industries such as electronics, medical technology, automotive, and new energy for product reliability validation. Within a limited footprint, they can simulate temperature cycling, humidity stress, and other complex environmental conditions, making them a vital tool for laboratories and quality assurance departments. Thanks to their ease of operation and high flexibility, the benchtop environmental chamber has become indispensable in both R&D and quality inspection processes.
However, no matter how advanced the equipment is, its performance will inevitably decline without systematic daily maintenance. Regular upkeep not only extends the service life of the chamber but also ensures the stability and accuracy of test data, ultimately reducing downtime and maintenance costs. Therefore, establishing a systematic and practical daily maintenance checklist is a critical step for any enterprise or laboratory using a benchtop environmental test chamber to ensure long-term efficiency and reliable testing outcomes.

Common Types of Benchtop Test Chambers and Their Applications

Before defining a maintenance checklist, it is important to understand the different types of benchtop test chambers and their typical applications.
  1. Benchtop Thermal Chamber Designed for rapid or cyclic switching between high and low temperatures, this chamber evaluates the stability of materials and components under extreme temperature conditions. Examples include insulation tests for electronic parts at high temperatures and mechanical strength testing at subzero conditions.
  2. Chambre d'humidité de table By precisely controlling temperature and humidity, this chamber simulates how products perform in humid or complex climate environments. It is widely used for testing the moisture resistance and long-term reliability of electronic circuit boards, plastics, and medical components.
  3. Chambre de température de table Focused on constant or gradient temperature control, this chamber is ideal for material performance studies, pharmaceutical stability testing, and performance evaluations of components under specific thermal conditions.
  4. Benchtop Vibration Tables Used to simulate mechanical vibrations and shocks that products may encounter during transportation, storage, or use. When combined with an environmental chamber, they enable comprehensive reliability testing that integrates temperature, humidity, and mechanical stress.
While the functions and applications of each type differ, their maintenance principles remain highly consistent. Regardless of the model, regular inspection and proper care are essential to ensure optimal long-term performance and consistent testing accuracy.

Liste de vérification de l'entretien quotidien pour les enceintes de test de laboratoire

  1. External and Environmental Maintenance

    • Surface Cleaning: Regularly wipe down the chamber exterior to prevent dust and oil buildup that could obstruct cooling vents or airflow.
    • Environnement Conditions: Place the equipment in a dry, well-ventilated laboratory environment, away from direct sunlight and heat sources. Excessive humidity may cause internal circuits to become damp, leading to short circuits or corrosion.
    • Stable Placement: Ensure the chamber is positioned on a level surface to avoid vibrations or tilting that could loosen or damage internal components.
  1. Electrical and Safety Checks

    • Power Supply Inspection: Verify that power cords are intact and plugs are secure before use to avoid malfunctions caused by poor connections.
    • Marge de volume: Choisissez une capacité légèrement plus grande que les besoins actuels pour accueillir les augmentations futures d'échantillons d'essai. Protection: Regularly check the grounding system to prevent risks of static discharge or leakage current.
    • Sécurité Device Testing: Functions such as over-temperature protection and door safety locks should be tested periodically to ensure proper response during abnormal conditions.
  1. Internal System Maintenance

    • Sensor Calibration: Temperature and humidity sensors are the core components of a benchtop environmental chamber and should be calibrated regularly to ensure accurate monitoring.
    • Sealing Gasket Inspection: Door seals should be checked for aging or cracks, as compromised seals affect temperature and humidity stability.
    • Humidity Control System: Keep the humidifier tank clean to prevent scale buildup from affecting atomization. Ensure the dehumidification system, including the condenser and drain pan, is free of blockages.
    • Refrigeration System Care: The compressor and condenser are critical parts of the chamber. Clean the condenser fins periodically to maintain airflow and prevent overheating shutdowns.
  1. Operational Best Practices

    • Preheating and Precooling: Follow the manufacturer’s guidelines for preheating or precooling before testing to avoid sudden load stress.
    • Proper Sample Placement: Arrange samples evenly without blocking airflow to ensure uniform temperature and humidity distribution.
    • Avoid Overloading: Respect the specified operating range for temperature and humidity. Do not exceed the limits.
    • Post-Test Care: After completing tests, wipe the chamber interior dry to prevent mold growth or corrosion from residual moisture.
  1. Data and Record Management

    • Test Logs: Record test parameters, runtime, and equipment performance after each use.
    • Maintenance Records: Document cleaning, component replacement, and calibration activities to create traceable maintenance archives.
    • Alarm Tracking: Record and investigate abnormal alarms such as over-temperature or humidity fluctuations to prevent recurring issues.

Additional Tips to Extend Service Life

  • Scheduled Professional Servicing: In addition to daily care, have the chamber inspected and serviced by the manufacturer or a qualified engineer at least once a year.
  • Use of Original Spare Parts: Always use OEM or certified components such as seals, sensors, and humidifier filters to ensure compatibility and reliability.
  • Operator Training: Personnel should be properly trained to understand the chamber’s functions and limitations, reducing risks of damage from improper use.
  • Smart Monitoring and Control: Many modern chambers, such as the benchtop temperature chamber, offer remote monitoring and control features. Leveraging these capabilities can greatly enhance management efficiency.

Conclusion

For users, adopting systematic daily maintenance practices is not only an effective way to reduce equipment failures and operating costs but also a critical guarantee of test accuracy and product quality. At the same time, choosing a trusted supplier is equally important.
As a professional manufacturer with deep expertise in environmental testing equipment, DHT® offers high-performance benchtop test chambers—including the Benchtop Thermal Chamber and Benchtop Humidity Chamber—along with comprehensive technical support and maintenance guidance. These solutions help enterprises consistently maintain an edge in product development and quality assurance.
If you are looking for a reliable, easy-to-maintain benchtop test chamber or would like professional maintenance advice, contact the DHT® expert team today. We provide tailored solutions to help your products enter the market faster and with greater reliability.