The DHT® Ventilated Aging Test Chamber is specifically designed to simulate environmental conditions that products may encounter during prolonged use, assessing their durability and reliability. By controlling internal factors such as temperature, humidity, and gas flow, the chamber accelerates the aging process of products, aiding in the evaluation of performance changes under various environmental conditions. This equipment is widely utilized in industries including electronics, electrical engineering, materials science, and automotive sectors, particularly for testing product durability, aging characteristics, and long-term stability.

Avantages

High-Quality Chamber Construction: The inner chamber is crafted from imported high-grade stainless steel (SUS304) mirror panels or 304B argon arc welded materials, while the outer casing is made from A3 steel plates with a spray coating, enhancing both the aesthetic appeal and cleanliness of the unit.

Intelligent Temperature Control System: Equipped with a microcomputer-based intelligent program controller featuring temperature control protection and a timing function, ensuring precise and reliable temperature regulation.

Uniform Temperature Distribution: The hot air circulation system comprises a fan capable of continuous operation at high temperatures and a specialized air duct, ensuring even temperature distribution within the chamber.

Safety Protection Features: Includes an independent over-temperature alarm system that automatically interrupts heating when the set temperature limit is exceeded, ensuring safe operation during experiments.

Efficient Ventilation Function: Ventilation time and frequency are adjustable, ensuring that atmospheric changes during testing meet the required specifications.

Convenient Testing Interface: The left side of the chamber is equipped with a 50mm diameter test hole, allowing for the connection of external test power lines or signal cables.

Vidéo des caractéristiques

Spécifications

Plage de température (℃) RT+10~300
Temperature Uniformity (℃) ±2
Temperature Fluctuation (℃) ±0.5
Ventilation Time (min, h) Adjustable from 1 minute to 99 hours
Air Exchange Rate (times/h 2 to 100 times/hour
Accuracy Range (℃) Setting Accuracy: ±0.1°C
Display Accuracy: ±0.1°C,Resolution: ±0.1°C
Rotating Tray Diameter (mm) 101:Φ250;225:Φ350;504:Φ500;
800:Φ600;010:Φ800
Power (kW 101:3;225:4.5;
504:5.5;800/010:6.5
Contrôleur Imported LED digital display, P.I.D + S.S.R.
Microcomputer integrated controller
Plage de temporisation (min) 1~9999
Système de circulation Moteur résistant aux hautes températures et silencieux avec ventilateur centrifuge multi-lames
Caractéristiques de sécurité Protection contre les fuites, les courts-circuits, les surchauffes, les surchauffes du moteur et les surintensités